Mechanical factors affecting the estimation of tibialis anterior force using an EMG-driven modelling approach

PhD thesis


Miller, S. 2014. Mechanical factors affecting the estimation of tibialis anterior force using an EMG-driven modelling approach. PhD thesis Brunel University Centre for Sports Medicine and Human Performance
TypePhD thesis
TitleMechanical factors affecting the estimation of tibialis anterior force using an EMG-driven modelling approach
AuthorsMiller, S.
Abstract

The tibialis anterior (TA) muscle plays a vital role in human movement such as walking and running. Overuse of TA during these movements leads to an increased susceptibility of injuries e.g. chronic exertional compartment syndrome. TA activation has been shown to be affected by increases in exercise, age, and the external environment (i.e. incline and footwear). Because activation parameters of TA change with condition, it leads to the interpretation that force changes occur too. However,activation is only an approximate indicator of force output of a muscle. Therefore, the overall aim of this thesis was to investigate the parameters affecting accurate measure of TA force, leading to development of a subject-specific EMG-driven model, which takes into consideration specific methodological issues. The first study investigated the reasons why the tendon excursion and geometric method differ so vastly in terms of estimation of TA moment arm. Tendon length changes during the tendon excursion method, and location of the TA line of action and irregularities between talus and foot rotations during the geometric method, were found to affect the accuracy of TA moment arm measurement. A novel, more valid, method was proposed. The second study investigated the errors associated with methods used to account for plantar flexor antagonist co-contraction. A new approach was presented and
shown to be, at worse, equivalent to current methods, but allows for accounting throughout the complete range of motion. The final study utilised the outputs from studies one and two to directly measure TA force in vivo. This was used to develop, and validate, an EMG-driven TA force model. Less error was found in the accuracy of estimating TA force when the contractile component length changes were modelled using the ankle, as opposed to the muscle. Overall, these findings increase our understanding of not only the mechanics associated with TA and the ankle, but also improves our ability to accurately monitor these.

Research GroupBiomechanics at the London Sport Institute
Department nameCentre for Sports Medicine and Human Performance
Institution nameBrunel University
Publication dates
Print30 Apr 2015
Publication process dates
Deposited30 Apr 2015
Completed2014
Output statusPublished
Accepted author manuscript
Web address (URL)http://bura.brunel.ac.uk/handle/2438/8763