Analytical dilemmas in lupus anticoagulant detection
Article
Moore, G. 2023. Analytical dilemmas in lupus anticoagulant detection. Exploration of Immunology. 3, pp. 300-324. https://doi.org/10.37349/ei.2023.00104
| Type | Article |
|---|---|
| Title | Analytical dilemmas in lupus anticoagulant detection |
| Authors | Moore, G. |
| Abstract | Accurate lupus anticoagulant (LA) detection is crucial to antiphospholipid syndrome (APS) diagnosis. Detection is based on LA functional behavior in coagulation assays irrespective of epitope specificity. LA screening tests employ dilute phospholipids to accentuate in vitro inhibition by LAs, although they are not LA-specific and can be elevated by other coagulation abnormalities. Elevated screening tests are reflexed to mixing tests to distinguish between factor deficiency and inhibition. Confirmatory tests with high phospholipid concentration swamp LA to generate shorter clotting times than screening tests, whilst prolongation persists with non-phospholipid-dependent inhibitors. LA heterogeneity means that no single screening test detects every LA and the screen/mix/confirm medley must be applied to at least two assay types, usually dilute Russell’s viper venom time (dRVVT) and an LA-sensitive activated partial thromboplastin time (aPTT). Most laboratories restrict LA testing to these two assays, yet others, such as dilute prothrombin time (dPT), can perform with equal diagnostic efficacy, and additionally detect LA unreactive with dRVVT and aPTT. Converting clotting times to normalized ratios improves assay performance, and practitioners must choose between normal pooled plasma (NPP) clotting time denominators to reflect on-the-day assay performance, or reference interval (RI) mean clotting times to negate the effects of NPP variation. Cut-offs can be generated parametrically from normally distributed data, or different percentiles applied depending on the preferred balance between sensitivity and specificity. Sourcing sufficient donors for accurate cut-off estimations is problematic and transference exercises can be undertaken on low donor numbers. Analytical limitations of mixing tests have led to the adoption of alternative algorithms to the screen/mix/confirm test order, whilst some continue to rigidly apply the latter despite those limitations. Strategies to reduce or eliminate the effects of therapeutic anticoagulation have limitations, whilst the Taipan snake venom time (TSVT) screening test with an ecarin time (ET) confirmatory test is insensitive to vitamin K antagonist (VKA) and direct activated factor X anticoagulation. |
| Sustainable Development Goals | 3 Good health and well-being |
| Middlesex University Theme | Health & Wellbeing |
| Publisher | Open Exploration Publishing |
| Journal | Exploration of Immunology |
| ISSN | |
| Electronic | 2768-6655 |
| Publication dates | |
| Online | 31 Aug 2023 |
| 31 Aug 2023 | |
| Publication process dates | |
| Submitted | 03 Jan 2023 |
| Accepted | 29 Mar 2023 |
| Deposited | 10 Nov 2025 |
| Output status | Published |
| Publisher's version | License File Access Level Open |
| Copyright Statement | © The Author(s) 2023. This is an Open Access article licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, sharing, adaptation, distribution and reproduction in any medium or format, for any purpose, even commercially, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
| Digital Object Identifier (DOI) | https://doi.org/10.37349/ei.2023.00104 |
https://repository.mdx.ac.uk/item/2yqy72
Download files
45
total views56
total downloads1
views this month2
downloads this month