Validation of finite element mesh warping for improving the forward model in EIT of brain function
Book chapter
Tizzard, A. and Bayford, R. 2007. Validation of finite element mesh warping for improving the forward model in EIT of brain function. in: Scharfetter, H. and Merwa, R. (ed.) IFMBE Proceedings, Part II - 13th International Conference on Electrical Bioimpedance and 8th Conference on Electrical Impedance Tomography 2007 Graz, Austria Springer Verlag.
Chapter title | Validation of finite element mesh warping for improving the forward model in EIT of brain function |
---|---|
Authors | Tizzard, A. and Bayford, R. |
Abstract | This group has previously presented methods for the rapid generation of patient-specific finite element (FE) models for use in EIT reconstruction using elastic deformation. In particular, the work has concentrated on the imaging of brain function, and methods for warping existing FE library models of varying complexity but with accurate anatomical details have been developed and reported. What is still unclear is how the use of the more accurate geometric form from the warped FE mesh improves the forward solution and the quality of reconstructed images. This paper presents initial results that validate this notion by comparison of boundary voltages, image quality and localization accuracy within a warped mesh with data from a simulated forward solution and phantom measurements. |
Keywords | Brain; EIT forward problem; finite-element analysis; Electrical impedance tomography |
Research Group | Biophysics and Bioengineering group |
Book title | IFMBE Proceedings, Part II - 13th International Conference on Electrical Bioimpedance and 8th Conference on Electrical Impedance Tomography 2007 |
Editors | Scharfetter, H. and Merwa, R. |
Publisher | Springer Verlag |
Place of publication | Graz, Austria |
ISBN | |
Hardcover | 9783540738404 |
Publication dates | |
2007 | |
Publication process dates | |
Deposited | 30 Aug 2012 |
Output status | Published |
Additional information | ID: 347; RP: IN FILE; 28 |
Web address (URL) | http://dx.doi.org/10.1007/978-3-540-73841-1_96 |
Language | English |
https://repository.mdx.ac.uk/item/81x1w
54
total views0
total downloads1
views this month0
downloads this month
Export as
Related outputs
Forearm motion and hand grasp prediction based on target muscle bioimpedance for Human-Machine Interaction
Yao, T., Wu, Y., Jiang, D., Bayford, R. and Demosthenous, A. 2025. Forearm motion and hand grasp prediction based on target muscle bioimpedance for Human-Machine Interaction. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 33, pp. 760-769. https://doi.org/10.1109/TNSRE.2025.3538609Chest EIT based on Lagrange Multipliers reconstruction
Seifnaraghi, N. and Bayford, R. 2024. Chest EIT based on Lagrange Multipliers reconstruction. Xie, L., Fu, F., Long, Y., Ge, H., Pan, Q. and Zhao, Z. (ed.) 24th International Conference on Biomedical Applications of Electrical Impedance Tomography. Hangzhou, China 27 - 30 Jun 2024A 1.76 mW, 355-fps, electrical impedance tomography system with a simple time-to-digital impedance readout for fast neonatal lung imaging
Li, J., Jiang, D., Wu, Y., Zhang, J., Seifnaraghi, N., Bayford, R. and Demosthenous, A. 2024. A 1.76 mW, 355-fps, electrical impedance tomography system with a simple time-to-digital impedance readout for fast neonatal lung imaging. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/JSSC.2024.3434638Progress in electrical impedance tomography and bioimpedance
Bayford, R., Sadleir, R., Frerichs, I., Oh, T. and Leonhardt, S. 2024. Progress in electrical impedance tomography and bioimpedance. Physiological Measurement. 45 (8). https://doi.org/10.1088/1361-6579/ad68c1A current DAC based current generator with fourth-order current-mode filter for electrical impedance tomography
Li, J., Wu, Y., Jiang, D., Bayford, R. and Demosthenous, A. 2024. A current DAC based current generator with fourth-order current-mode filter for electrical impedance tomography. 2024 IEEE International Symposium on Circuits and Systems. Singapore, Singapore 19 - 22 May 2024 IEEE. pp. 1-4 https://doi.org/10.1109/iscas58744.2024.10558679Clinical utility of ultrasound imaging for measuring anterior thigh thickness after anterior cruciate ligament injury in an individual patient to assess postsurgery outcome
Mechelli, F., Bayford, R., Garelick, H., Stokes, M. and Agyapong-Badu, S. 2023. Clinical utility of ultrasound imaging for measuring anterior thigh thickness after anterior cruciate ligament injury in an individual patient to assess postsurgery outcome. Case Reports in Orthopedics. 2023. https://doi.org/10.1155/2023/6672951Live demonstration: real time imaging with electrical impedance tomography
Zohoori, S., Rahal, M., Habibollahi, M., Jiang, D., Wu, Y., Bardill, A., Seifnaraghi, N., Yerworth, R., Bayford, R. and Demosthenous, A. 2023. Live demonstration: real time imaging with electrical impedance tomography. 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS). Toronto, Canada 19 - 21 Oct 2023 IEEE. https://doi.org/10.1109/BioCAS58349.2023.10388836Live demonstration: a bioimpedance-based robotic hand control platform using a customised neural network
Yao, T., Almarri, N., Wu, Y., Jiang, D., Bayford, R. and Demosthenous, A. 2023. Live demonstration: a bioimpedance-based robotic hand control platform using a customised neural network. 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS). Toronto, Canada 19 - 21 Oct 2023 IEEE. https://doi.org/10.1109/biocas58349.2023.10389001A compact neural network for high accuracy bioimpedance-based hand gesture recognition
Yao, T., Wu, Y., Jiang, D., Bayford, R. and Demosthenous, A. 2023. A compact neural network for high accuracy bioimpedance-based hand gesture recognition. 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS). Toronto, Canada 19 - 21 Oct 2023 IEEE. https://doi.org/10.1109/biocas58349.2023.10388679Effect of routine suction on lung aeration in critically ill neonates and young infants measured with electrical impedance tomography
Händel, C., Becher, T., Miedema, M., Kallio, M., Papadouri, T., Waldmann, A.D., Sophocleous, L., Yerworth, R., Bayford, R., Rimensberger, P.C., van Kaam, A.H. and Frerichs, I. 2023. Effect of routine suction on lung aeration in critically ill neonates and young infants measured with electrical impedance tomography. Scientific Reports. 13 (1). https://doi.org/10.1038/s41598-023-42965-7An 89.3% current efficiency, sub 0.1% THD current driver for electrical impedance tomography
Li, J., Jiang, D., Wu, Y, Neshatvar, N., Bayford, R. and Demosthenous, A. 2023. An 89.3% current efficiency, sub 0.1% THD current driver for electrical impedance tomography. IEEE Transactions on Circuits and Systems II: Express Briefs. 70 (10), pp. 3742-3746. https://doi.org/10.1109/TCSII.2023.3294753Thermodynamics of mechanopeptide sidechains
Haque, M., Kadir, M. and Bayford, R. 2023. Thermodynamics of mechanopeptide sidechains. AIP Advances. 13 (8). https://doi.org/10.1063/5.0154129Effects of patient recumbency position on neonatal chest EIT
Seifnaraghi, N., De Gelidi, S., Frerichs, I., Kallio, M., Sorantin, M., Demosthenous, A. and Bayford, R. 2023. Effects of patient recumbency position on neonatal chest EIT. IEEE Access. 11, pp. 68257 - 68268. https://doi.org/10.1109/ACCESS.2023.3290904Prolonged continuous monitoring of regional lung function in infants with respiratory failure
Becher, T.H., Miedema, M., Kallio, M., Papadouri, T., Karaoli, C., Sophocleous, L., Rahtu, M., Van Leuteren, R.W., Waldmann, A.D., Strodthoff, C., Yerworth, R., Dupré, A., Benissa, M.-R., Nordebo, S., Khodadad, D., Bayford, R., Vliegenthart, R., Rimensberger, P.C., Van Kaam, A.H. and Frerichs, I. 2022. Prolonged continuous monitoring of regional lung function in infants with respiratory failure . Annals of the American Thoracic Society. 19 (6), pp. 873-1080. https://doi.org/10.1513/AnnalsATS.202005-562OCA low power, low THD current driver with discrete common-mode feedback for EIT applications
Li, J., Wu, Y., Bayford, R., Jiang, D. and Demosthenous, A. 2022. A low power, low THD current driver with discrete common-mode feedback for EIT applications . 29th IEEE International Conference on Electronics, Circuits and Systems. Glasgow, UK 24 - 26 Oct 2022 IEEE. https://doi.org/10.1109/ICECS202256217.2022.9971123Generation of anatomically inspired human airway tree using electrical impedance tomography: A method to estimate regional lung filling characteristics
Zamani, M., Kallio, M., Bayford, R. and Demosthenous, A. 2022. Generation of anatomically inspired human airway tree using electrical impedance tomography: A method to estimate regional lung filling characteristics. IEEE Transactions on Medical Imaging. 41 (5), pp. 1125-1137. https://doi.org/10.1109/TMI.2021.3136434Advances in electrical impedance tomography and bioimpedance including applications in COVID-19 diagnosis and treatment
Bayford, R., Rosalind, S. and Frerichs, I. 2022. Advances in electrical impedance tomography and bioimpedance including applications in COVID-19 diagnosis and treatment. Physiological Measurement. 43 (2). https://doi.org/10.1088/1361-6579/ac4e6cA low-power recursive I/Q signal generator and current driver for bioimpedance applications
Hanzaee, F., Neshatvar, N., Rahal, M., Jiang, D., Bayford, R. and Demosthenous, A. 2022. A low-power recursive I/Q signal generator and current driver for bioimpedance applications. IEEE Transactions on Circuits and Systems II: Express Briefs. 69 (10), pp. 4108-4112. https://doi.org/10.1109/TCSII.2022.3187076High frame rate electrical impedance tomography system for monitoring of regional lung ventilation
Rahal, M., Dai, J., Wu, Y., Bardill, A., Bayford, R. and Demosthenous, A. 2022. High frame rate electrical impedance tomography system for monitoring of regional lung ventilation. 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). Glasgow, Scotland, United Kingdom 11 - 15 Jul 2022 IEEE. pp. 2487-2490 https://doi.org/10.1109/EMBC48229.2022.9871479Development of a biosensor for fast point-of-care blood analysis of Troponin
Bayford, R., Damaso, R., Jiang, D., Rahal, M. and Demosthenous, A. 2022. Development of a biosensor for fast point-of-care blood analysis of Troponin. 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). Glasgow, Scotland, United Kingdom 11 - 15 Jul 2022 IEEE. pp. 910-913 https://doi.org/10.1109/EMBC48229.2022.9871851Bronchodilator effect on regional lung function in pediatric viral lower respiratory tract infections
Strodthoff, C., Kähkönen, T., Bayford, R., Becher, T., Frerichs, I. and Kallio, M. 2022. Bronchodilator effect on regional lung function in pediatric viral lower respiratory tract infections. Physiological Measurement. 43 (10). https://doi.org/10.1088/1361-6579/ac9450