Validity and reliability of a phone App and stopwatch for the measurement of 505 change of direction performance: a test-retest study design
Article
Chen, Z., Bian, C., Liao, K., Bishop, C. and Li, Y. 2021. Validity and reliability of a phone App and stopwatch for the measurement of 505 change of direction performance: a test-retest study design. Frontiers in Physiology. 12, pp. 1-8. https://doi.org/10.3389/fphys.2021.743800
Type | Article |
---|---|
Title | Validity and reliability of a phone App and stopwatch for the measurement of 505 change of direction performance: a test-retest study design |
Authors | Chen, Z., Bian, C., Liao, K., Bishop, C. and Li, Y. |
Abstract | Purpose: The aim of this study was to explore the validity and reliability of a phone app (named: COD timer) and stopwatches for the measurement of change of direction (COD) performance. Methods: Sixty-two youth basketball players (age: 15.9 ± 1.4 yrs, height: 178.8 ± 11.0 cm, body mass: 70.0 ± 14.1 kg) performed six trials of 505 COD test (with the left side being the plant leg first, then the right side). The completion time was measured simultaneously via timing gates (with error correction processing algorithms), the phone app and stopwatches. Results: There was an almost perfect correlation and agreement between timing gates and COD timer (r = 0.978; SEE = 0.035 s; LoA =-0.08~0.06 s), but a lower correlation and agreement between timing gates and stopwatch (r = 0.954; SEE = 0.050 s; LoA =-0.17~0.04 s) with statistical significance in completion time (ES = 1.29, 95%CI: 1.15-1.43, p < 0.01). The coefficient of variation revealed similar level of dispersion between the three timing devices (timing gates: 6.58%; COD timer: 6.32%; stopwatch: 6.71%). Inter-observer reliability (ICC = 0.991) and test-retest reliability (ICC = 0.998) were excellent in COD timer, while the inter-observer reliability was lower (ICC = 0.890) in the stopwatches. Conclusion: In the 505 COD test, the COD timer was able to provide a valid and reliable measurement. On the contrary, stopwatch was not recommended because of large error. Thus, if timing gates are unavailable, practitioners can adopt the COD timer app to assess 505 COD speed times. |
Keywords | Physiology, adolescent, basketball, change of direction, smartphone, timing device |
Research Group | Strength and Conditioning at the London Sport Institute |
Publisher | Frontiers Research Foundation |
Journal | Frontiers in Physiology |
ISSN | 1664-042X |
Publication dates | |
24 Sep 2021 | |
Publication process dates | |
Deposited | 27 Aug 2021 |
Submitted | 19 Jun 2021 |
Accepted | 23 Aug 2021 |
Output status | Published |
Publisher's version | License |
Accepted author manuscript | File Access Level Restricted |
Copyright Statement | Copyright © 2021 Chen, Bian, Liao, Bishop and Li. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |